Confirm the installed model against the enclosure drawing before testing. Vent plugs with identical mounting threads do not necessarily provide the same airflow.
|
Parameter |
|||
|
Thread size |
M3 × 0.5 |
M4 × 0.7 |
M4 × 0.7 |
|
Airflow at 1 kPa |
3 mL/min |
3 mL/min |
9 mL/min |
|
Published water-blocking pressure |
−120 mbar |
−120 mbar |
−120 mbar |
|
Operating temperature |
−50°C to +150°C |
−50°C to +150°C |
|
|
Protection options |
IP67/IP68 |
IP67/IP68 |
IP67/IP68 |
The HA-4A and HA-4A-2 both use M4 × 0.7 threads, but the HA-4A-2 has three times the published airflow at 1 kPa.
Check the required airflow, mounting clearance and enclosure volume before replacing one model with another. Confirm the protection rating and test conditions for the selected configuration.
Before connecting the flow meter or conducting a water ingress test, inspect the following areas:
A vent plug that appears securely tightened may still have an improperly compressed seal. Inspect the mounting surface and sealing ring rather than relying on tightening force alone.
For component-level testing, mount the vent plug in a suitable test fixture and check the fixture for unintended leakage.
Establish the specified pressure differential, allow the reading to stabilize and record the measured airflow.
For the HA-3A and HA-4A, the published airflow is 3 mL/min at 1 kPa. The HA-4A-2 provides a published value of 9 mL/min under the same pressure differential.
Use the approved test specification to determine the acceptable airflow range.
When testing an assembled enclosure, leakage through cover seals or cable glands can affect the results. An unusually high airflow reading may indicate unwanted leakage rather than better ventilation.
Where practical, measure background leakage with the vent passage isolated before evaluating the installed vent.
Water can enter through the vent element, around the sealing ring or through other enclosure joints.
The published water-blocking pressure of −120 mbar is a component specification. It does not define the immersion depth or test duration for the complete enclosure.
For equipment requiring IP67 or IP68 protection, select the applicable IEC 60529 test procedure and confirm the required test conditions.
After testing, inspect the internal area beneath the vent, the mounting interface and other enclosure openings for water ingress.
|
Problem |
Possible cause |
Inspection or corrective action |
|
Water around the mounting hole |
Damaged O-ring or uneven surface |
Inspect the seal and mounting surface |
|
Sealing ring extrusion |
Excessive tightening |
Check assembly torque and seal geometry |
|
Low airflow |
Dust, oil or blocked openings |
Inspect the vent passage and membrane |
|
Abnormally high airflow |
Fixture or enclosure leakage |
Check background leakage |
|
Slow pressure equalization |
Restricted airflow or insufficient vent capacity |
Review enclosure volume and model selection |
Avoid inserting sharp tools into the ventilation opening. Unapproved solvents may also damage the membrane or sealing components.
If a vent fails inspection, identify the cause before replacing it. Installing a new component will not correct a defective mounting surface.
Record the actual test conditions and measured values for each inspected assembly.
|
Inspection item |
Record |
|
Vent plug model and batch |
- |
|
Mounting and sealing condition |
- |
|
Installation torque |
- |
|
Airflow test pressure |
- |
|
Measured airflow |
- |
|
Waterproof test conditions |
- |
|
Water ingress result |
- |
|
Corrective action |
- |
|
Final result |
Pass / Fail |
Xi'an Hoan Microwave Co., Ltd. supplies threaded waterproof vent plugs for electrical enclosures, outdoor equipment and industrial electronics.
For compact mounting applications, the HA-3A offers an M3 thread. The HA-4A and HA-4A-2 provide M4 mounting options with different airflow capacities.
For model selection or installation evaluation, send HOAN your enclosure drawing, mounting dimensions, required airflow, operating temperature and target IP protection level.
Visit https://www.hoanisolators.com/ for product specifications and technical support.
No. The finished enclosure requires separate verification, including its mounting interfaces, cover seals and cable entries.
Common causes include blocked ventilation openings, membrane contamination and interference from internal enclosure components.
They share the same M4 × 0.7 thread but have different airflow capacities. Check the mounting dimensions and ventilation requirements before replacement.