Key Features
• Vibration Absorption: By utilizing materials such as wire ropes and rubber pads, the GX effectively absorbs vibration energy caused by earthquakes or wind, reducing the impact on the building.
• Enhanced Seismic Performance: By reducing vibration amplitude, the GX improves the building’s seismic resistance, allowing it to better withstand natural disasters such as earthquakes.
• Improved Comfort: By minimizing structural vibrations, the GX enhances the comfort inside the building, creating a more stable and safe living or working environment.
• Reliability and Durability: Constructed with durable materials and a robust design, the GX offers high reliability and long-lasting protection for building structures against external vibrations.
product details
| Model | L(mm) | A±0.3 | H±1.5 | W±1.5 | d | Loops | Rubber Pad Dimensions |
| GX-10A(N) | 55 | 49 | 21 | 26 | M3-7H | 6 | 46*12*8 |
| GX-20A(N) | 84 | 68 | 29 | 35 | M5-7H | 6 | 62*14*10 |
| GX-30A(N) | 113 | 97 | 32.5 | 40 | M5-7H | 8 | 91*14*15 |
| GX-40A(N) | 113 | 97 | 32.5 | 40 | M5-7H | 8 | 91*14*15 |
| GX-50A(N) | 113 | 97 | 33 | 40 | M5-7H | 10 | 91*14*15 |
| GX-60A(N) | 133 | 117 | 31 | 40 | M5-7H | 10 | 108*14*12 |
Product Technical Data Sheet
| Technical Parameter | Model | |
| GX-A | GX-AN | |
| Pz Nominal Load(N) | 10~60 | |
| Deflection |
|
|
| Resonance Magnification | ≤4 | |
| High Frequency Efficiency | ≥95 | |
| Working Temperature(℃) | -55~+125 | |
| Shock(Ks) | 30g/11ms | 100g/6ms |
| Peak Respones G | ≤3.5km/s2 | |
Vibration & Shock Resistance Curve